The Model SLVAC-0102-70M OPTION LA is a Miniature Successive
Detection Log Video Amplifier (SDLVA) Implemented with
Wideband Hybrid MIC/MMIC Technology operating over the 120
MHz to 200 MHz bandwidth and able to detect noise in the 10
MHz to 1 GHz range.

Specifications:
Frequency Range |
130 to 190 MHz |
Dynamic Range |
+5 dBm to -65 dBm |
RF Input Impedance |
50 ohms |
Input VSWR |
1.8:1, 1.5:1 Typical |
Maximum Power |
15 dBm |
Load Impedance |
93 ohms |
Log Video Output Impedance |
Source Impedance ≤1 ohm |
Log Video Output Voltage |
@-60 dBm +375 mV ±100 mV
at 160 MHz @ 0 dBm +1.875 V ±100 mV |
Log Video Linearity |
±1 dB @ 25 degrees C
±1.5 dB over Operating
Temperature Range |
Log Video Baseline |
-75 dBm Minimum |
Tangential Sensitivity |
-72 dBm Minimum |
Log Video Versus Frequency |
±1 dB |
Log Video Versus Temperature |
±2.25 dB |
Log Video Rise Time |
32 nS Maximum |
Log Video Fall Time |
35 nS Maximum |
Log Video Bandwidth |
15 MHz to 30 MHz Maximum |
RF Output VSWR |
2.5:1 |
RF Output Impedance |
50 ohms |
Limited RF Output Level |
+2 dBm ±1 dBm |
Limited RF Output Phase Versus Amplitude |
±0.3 degrees / dB |
Phase Tracking Versus Frequency |
Any two units shall track within ±2 degrees |
DC Power |
+5V ±0.25V @ 100 mA, -5V ±0.25V @ 200 mA |
DC Power Supply Protection |
+6.5 V Maximum, -6.5V Minimum |
Available Options:
Please contact the factory for
additional options.
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-40ºC to +71 ºC Operating |
| -65
ºC to +100 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click
here to see an outline drawing of SLVAC-0102-70M OPT: LA
Product Feature:
Product Feature on
SLVAC-0102-70M OPT: LA
Test Report:
Test
Report on SLVAC-0102-70M OPT: LA
Test Data (06/19/01):
Test Data on SLVAC-0102-70M OPT: LA
More Test Data (02/07/05):
More Test Data on SLVAC-0102-70M OPT: LA
More Test Data (04/01/05):
More Test Data on SLVAC-0102-70M OPT: LA
More Test Data
(12/07/05):
More Test Data on SLVAC-0102-70M OPT: LA
More Test Data (02/08/06):
More Test Data on SLVAC-0102-70M OPT: LA
More Test Data
(02/01/07):
More Test Data on SLVAC-0102-70M OPT: LA
More Test Data
(09/20/07):
More Test Data on SLVAC-0102-70M OPT: LA
Press Release:
Press Release on SLVAC-0102-70M OPT: LA3
Press Release:
Another Press Release on SLVAC-0102-70M OPT: LA3
Acceptance Test Procedure
(ATP):
Acceptance Test Procedure on SLVAC-0102-70M OPT: LA
Mean Time Between Failures (MTBF)
Analysis:
Mean Time Between Failures (MTBF) Analysis on SLVAC-0102-70M
OPT: LA
Qual Approval for ATP
(08/29/07):
Qual Approval for ATP
Qual Approval for
Reliability Prediction (09/04/07):
Qual Approval for Reliability Prediction
Qual Approval for
Qualification by Similiarity (09/27/07):
Qual Approval for SLVAC-0102-70M OPT: LA
Acceptance Test Procedure
(ATP) on Standard SDLVA Chip:
Acceptance
Test Procedure (ATP) on Standard SDLVA Chip
Further Information:
Click
here to view our short form page on our Successive Detection
Log Video Amplifiers



|