PMI Model TD-30T-218-FC-HS
is a high speed threshold detector designed to operate over 2
to 18 GHz frequency range. It has an external adjustment to
vary the threshold level from -10 dBm to -20 dBm, with an
input flatness of typically +/-1.0 dB and VSWR of less than
3.0:1. This unit comes in a very small size with field
removable SMA connectors for surface mounting or typical
coaxial connection.

Specifications:
Frequency Range |
2.0 GHz to 18.0 GHz Minimum |
VSWR |
3.0:1 Maximum |
Dynamic Range |
-20 dBm to -10 dBm Minimum
(-20 dBm to +5 dBm Typical) |
Input Flatness |
+/-2.0 dB Maximum, (+/-1.0 dB
Typical) |
Response Time |
100 nS Maximum, (50 nS
Typical) |
Output |
TTL |
Power Supply |
+12V @ 100 mA Maximum |
RF Connector |
Removable SMA (Female) |
Output Connector |
Removable SMA (Female) |
Threshold Adjust |
Solder Pin |
Size |
0.80" x 0.62" x 0.40" |
Weight |
0.50 Ounce |
Available Options:
Please contact the factory for
additional options.
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-55
ºC to +85 ºC Operating |
| -65
ºC to +125 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click
here to see an outline drawing of TD-30T-218-FC-HS
Product Feature:
Product Feature on TD-30T-218-FC-HS
Test Report:
Test Data
on TD-30T-218-FC-HS. Threshold Detector designed to
operate over 2 to 18 GHz Frequency Range
Test Data (09/03/04):
Test
Data on TD-30T-218-FC-HS
Test Data (02/23/07):
Test Data on TD-30T-218-FC-HS
Test Data (02/11/08):
Test Data on TD-30T-218-FC-HS
Press Release:
Press Release
on TD-30T-218-FC-HS
Further Information:
Click here
to view our short form page on our Threshold Detectors
|