PMI Model TD-A-42T-818 is a
Hermetically Sealed Threshold Detector optimized for the 8 to
18 GHz Frequency Range. It has an internally fixed Threshold
Level providing a Minimum Signal Level of -42 dBm and a
Maximum Input VSWR of 2.5:1. The Threshold Setting Stability
is constant +/-3.0 dB over the operating temperature and
frequency.

Specifications:
Frequency Range |
8 GHz to 18 GHz |
Input Operating Range |
-30 dBm to -42 dBm (8-18 GHz) |
Input VSWR |
2.5:1 (8-18 GHz) |
Threshold Level |
Internally fixed to provide a
Minimum Signal Level of -42 dBm |
Threshold Setting Stability |
+/-3.0 dB over the Operating
Temperature and Frequency Time |
Maximum Power Input |
+10 dBm (Without Damage) |
Detected Output |
The Detector Output Signal
shall be a TTL Level high when the RF Signal applied to
the RF Input exceeds the threshold level. Any Signals
below the Threshold Level shall result in an output level
of TTL Low (0) the TTL output shall be buffered in such
that output loading has no effect on detector response.
The detected output shall have a drive capacity of at
least two standard TTL loads. |
Response Time |
For any RF input greater than
3 dB above Threshold. The maximum turn on response time
measured at 90% RF to a TTL "1" output shall be 100 uS.
The maximum turn off response time measured at 10% RF to a
TTL "0" shall be 100 uS. |
Connectors |
The Input Signal Connector
shall be a SMA Female in accordance with MIL-C-39012.
The Output Signal Connection shall be a Solderable Pin
(Diameter of 0.023" Minimum) with a Ground Lug next to
it. The Power Connection shall be a solderable pin
(Diameter of 0.023" Minimum). |
Power Supply Voltage |
+12V @ 200 mA Maximum |
Size |
1.50" (L) x 1.50" (W) x 0.50"
(H) |
Weight |
2.0 Ounces |
Available Options:
Please contact the factory for
additional options.
Environmental Ratings:
| Our standard
environmental ratings are as follows, for specific
requirements please contact us... |
|
Temperature: |
-55
ºC to +85 ºC Operating |
| -65
ºC to +125 ºC Non-Operating |
| Humidity: |
MIL-STD-202F,
Method 103B Cond. B |
| Shock: |
MIL-STD-202F,
Method 213B Cond. B |
| Vibration: |
MIL-STD-202F,
Method 204D Cond. B |
| Altitude: |
MIL-STD-202F,
Method 105C Cond. B |
|
Temperature Cycle: |
MIL-STD-202F,
Method 107D Cond. A |
|
Outline Drawing:
Click
here to see an outline drawing of TD-A-42T-818
Product Feature:
Product Feature on
TD-A-42T-818
Test Report:
Test Data on
TD-A-42T-818 Threshold Detector designed for the 8 to 18 GHz
Frequency Range
Press Release:
Press
Release on TD-A-42T-818
Further Information:
Click here