Planar Monolithics Industries, Inc. is very proud to announce that effective December 17, 2003 PMI has become ISO 9001:2000 Certified for the following scope of registration: Research, Development, Custom Design and Manufacture of RF/ Microwave Components, Super Components and Subsystems, in the DC to 40 GHz Frequency Range.  Please click here to see PMI's ISO Certificate.


 

PMI MODEL NUMBER: SDLVA-100M-80-SS

 
PMI Model SDLVA-100M-80-SS is a Successive Detection Log Video Amplifier that operates at the center frequency of 100 MHz with an input dynamic range of 80 dB.  A -3 dB Bandwidth of 20 MHz, Transfer Slope of 25 mV/dB and Rise Time of 30 nS.  These units are designed using cutting edge GaAs technology which provides stunning performance and reliability in a compact package.

Specifications:

  Center Frequency: 100 MHz
  -3 dB Bandwidth: 20 MHz
  Input Dynamic Range -80 dBm to 0 dBm
  Transfer Slope: 25 mV/dB Typical
  Log Linearity (@ Room Temperature): +/-0.5 dB Maximum
  Log Linearity (@ -30 to +85C): +/-1.0 dB Maximum
  Rise Time: 3 Maximum (In any 50 MHz segment)

(10% RF Input Pulse to 90% Video Output Pulse)

  Video Output @ 0 dBm into 50 ohms: 2.0V Typical
  Limited IF Output: 0 dBm +/- 1.0 dB
  Matched in pairs:

   Matching Characteristics

          Linearity @ Room Temperature:

          Linearity @ -30 to +85

          Temperature Compensation

 

 

+/-0.5 dB Maximum

+/-1.0 dB Maximum

 

  Operating Temperature: -30C to +85C
  Storage Temperature: -40C to +85V
  Power Consumption: +15 VDC @ 100 mA

-15 VDC @ 100 mA

  Size: 3.00" (L) x 2.00" (W) x 0.35" (H)
  Weight: 3.0 Ounces Typical

 

Available Options:

Please contact the factory for additional options.

 

Environmental Ratings:

 

Our standard environmental ratings are as follows, for specific requirements please contact us...
 Temperature:  -55 C to +85 C Operating
 -65 C to +125 C Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A

 

 

Outline Drawing: