Planar Monolithics Industries, Inc. is very proud to announce that effective December 17, 2003 PMI has become ISO 9001:2000 Certified for the following scope of registration: Research, Development, Custom Design and Manufacture of RF/ Microwave Components, Super Components and Subsystems, in the DC to 40 GHz Frequency Range.  Please click here to see PMI's ISO Certificate.


 

PMI MODEL NUMBER: VCAM-002000-90

 
PMI Model Number VCAM-002000-90 is a Voltage Controlled MMIC Modulator/Attenuator Designed to
Operate at 1.4 GHz Frequency
300 MHz.

Specifications:

  Frequency Range 1.4 GHz 300 MHz
  RF Input VSWR 2.0:1
  RF Output VSWR 2.0:1
  Insertion Loss 7 dB Maximum
  Isolation (Maximum Attenuation) 80 dB Minimum, 90 dB Typical
  Pulse Rise Time 50 nSec Typical, 100 nSec Maximum
  Pulse Fall Time 50 nSec Typical, 100 nSec Maximum
  DC Power +9V TO +15V 25 mA
  DC Power -9V TO -15V 25 mA

 

Available Options:

Please contact the factory for additional options.

 

Environmental Ratings:

 

Our standard environmental ratings are as follows, for specific requirements please contact us...
 Temperature:  -65 C to +110 C Operating
 -65 C to +125 C Non-Operating
 Humidity:  MIL-STD-202F, Method 103B Cond. B
 Shock:  MIL-STD-202F, Method 213B Cond. B
 Vibration:  MIL-STD-202F, Method 204D Cond. B
 Altitude:  MIL-STD-202F, Method 105C Cond. B
 Temperature Cycle:  MIL-STD-202F, Method 107D Cond. A

 

 

Outline Drawing:

Click here to see an outline drawing of VCAM-002000-90

 

Product Feature:

Product Feature on VCAM-002000-90

 

Test Report:

Test Data on DC to 2.4 GHz 100 dB Dynamic Range Ultra-Low Video Transient High speed Voltage Variable Matched MMIC Attenuator/Modulator

 

Test Data (10/09/97):

Test Data on VCAM-002000-90

 

Test Data (01/29/05):

Test Data on VCAM-002000-90

 

Test Data (10/13/05):

Test Data on VCAM-002000-90

 

Test Data (06/03/06):
Test Data on VCAM-002000-90